Description
FT-MTRC-DG3CA CFP transceivers are designed for use in 100Gigabit Ethernet links and OTU4 over 10km single module fiber, and it compliant to the CFP MSA and IEEE 802.3ba 100GBASE-LR4. Digital diagnostics are available via MDIO as specified in the CFP MSA Management Interface Specification.
The transceiver's designs are optimized for high performance and cost efficiency to provide customers the best solutions for Datacom and Telecom applications.
Features
● Up to10km transmission on SMF
● Support Dual Rate 103.1G and 111.8Gbps
● Transmitter:4-lane*28Gb/s LAN-WDM EML TOSA (1295.56nm,1300.05nm,1304.58nm,1309.14nm)
● Receiver:4-lane*28Gb/s PIN ROSA
● 10*10G Electrical Serial Interface (CAUI/OTL4.10)
● MDIO management interface with Digital Diagnostic
● CFP MSA package with duplex LC connector
+3.3V power supply
● Power consumption less than 12W l Operating case temperature: 0~+70°C
Applications
● 100GE Routers and Switches
● 100G DWDM/OTN
● 100G Network Security
Compliance
● Compliant with IEEE 802.3ba 100GBASER-LR4 l
● Compliant with ITU-T 411-9D1F
● Compliant with CFP MSA Hardware Specification Rev1.4
● Compliant with CFP MSA MDIO Specification Rev1.4
Absolute Maximum Ratings |
|
|
|
|
|
Parameter |
Symbol |
Conditions |
Min. |
Max. |
Unit |
Storage Temperature(Case) |
TS |
|
-40 |
+85 |
℃ |
Relative Humidity |
RH |
|
5 |
+85 |
% |
Damage Threshold for Receiver |
Pmax |
|
- |
+10.0 |
dBm |
Power Supply |
Vcc |
|
-0.3 |
+3.6 |
V |
ESD Sensitivity on module and all host pins |
HBM |
Human Body model R=1.5K, C=100pF |
- |
2000 |
V |
Specification
Recommended Operating Conditions |
|
|
|
|
|
Parameter |
Symbo● |
Min. |
Typical |
Max. |
Unit |
Operating Case Temperature |
Tc |
0 |
- |
+70 |
℃ |
Supply voltage |
Vcc 3.3V |
+3.14 |
+3.3 |
+3.47 |
V |
Supply Current |
Icc 3.3V |
- |
- |
3.3 |
A |
Power dissipation |
P |
- |
- |
12 |
W |
Low Power dissipation |
PLow |
|
|
2 |
W |
In-rush Curent |
I-inrush |
|
|
50 |
mA/us |
Turn-off rush Curent |
I-turnoff |
-50 |
|
|
mA/us |
Link Distance |
L |
2M |
- |
10km |
|
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.